相似文献/References:
[1]杨晓林,王烟平.地铁车辆辅助逆变器过流保护的原因分析及改进[J].机车电传动,2015,(03):82.[doi:10.13890/j.issn.1000-128x.2015.03.023]
[2]张 晓,王佳佳,刘长清,等.辅助逆变器散热器的数值模拟与优化设计[J].机车电传动,2015,(05):42.[doi:10.13890/j.issn.1000-128x.2015.05.012]
ZHANG Xiao,WANG Jiajia,LIU Changqing,et al.Numerical Simulation and Optimization Design of Auxiliary Power Inverter Heatsink[J].Electric Drive for Locomotives,2015,(06):42.[doi:10.13890/j.issn.1000-128x.2015.05.012]
[3]张兴宝,唐家龙,李 涛.西安地铁2 号线车辆司控器级位错乱故障的原因分析及整改方案[J].机车电传动,2015,(05):84.[doi:10.13890/j.issn.1000-128x.2015.05.023]
[4]陈 燕.受电弓状态动态检测系统在成都地铁2 号线的应用[J].机车电传动,2015,(05):91.[doi:10.13890/j.issn.1000-128x.2015.05.025]
CHEN Yan.Application of the Pantograph Dynamic Detection System in Chengdu Metro Line 2[J].Electric Drive for Locomotives,2015,(06):91.[doi:10.13890/j.issn.1000-128x.2015.05.025]
[5]刘高坤,张江,王树森,等.直线电机地铁车辆动力学性能仿真研究的新方法[J].机车电传动,2015,(02):103.[doi:10.13890/j.issn.1000-128x.2015.02.025]
LIU Gaokun,ZHANG Jiang,WANG Shusen,et al.New Method of Dynamics Performance Simulation for Metro Vehicle with Linear Motor[J].Electric Drive for Locomotives,2015,(06):103.[doi:10.13890/j.issn.1000-128x.2015.02.025]
[6]王寿峰,由建宏.地铁车辆空气弹簧压力急升引起总风欠压开关动作的对策[J].机车电传动,2014,(06):78.[doi:10.13890/j.issn.1000-128x.2014.06.021]
WANG Shoufeng,YOU Jianhong.Measures of Air Spring Pressure Rapid Rising Resulting in Main Air Switch Triggered for Metro Vehicle[J].Electric Drive for Locomotives,2014,(06):78.[doi:10.13890/j.issn.1000-128x.2014.06.021]
[7]高永军,张瑞峰.零电流软开关DC/DC电压变换输入型辅助逆变器[J].机车电传动,2014,(05):17.[doi:10.13890/j.issn.1000-128x.2014.05.005]
GAO Yongjun,ZHANG Ruifeng.Auxiliary Inverter with Zero-current Soft Switching DC/DC Converter Input[J].Electric Drive for Locomotives,2014,(06):17.[doi:10.13890/j.issn.1000-128x.2014.05.005]
[8]周晓明,肖华,陈超录.长沙地铁2号线车辆三大核心系统集成[J].机车电传动,2014,(04):1.[doi:10.13890/j.issn.1000-128x.2014.04.001]
ZHOU Xiao-ming,XIAO Hua,CHEN Chao-lu.Three Core Systems Integration in Changsha Metro Line 2[J].Electric Drive for Locomotives,2014,(06):1.[doi:10.13890/j.issn.1000-128x.2014.04.001]
[9]马喜成,李梁,刘家栋,等.地铁车辆客室门门间距取值分析与建议[J].机车电传动,2014,(04):65.[doi:10.13890/j.issn.1000-128x.2014.04.017]
MA Xi-cheng,LI Liang,LIU Jia-dong,et al.Analysis and Suggestion on Distances between the Centers of Adjacent Passenger Doors for Metro Vehicle[J].Electric Drive for Locomotives,2014,(06):65.[doi:10.13890/j.issn.1000-128x.2014.04.017]
[10]肖滋洪.地铁车辆高压供电电路过流故障诊断分析及改进[J].机车电传动,2014,(04):73.[doi:10.13890/j.issn.1000-128x.2014.04.019]
[11]严志勇,曾明高,罗国永,等.地铁车辆辅助逆变器的并网控制[J].机车电传动,2015,(04):59.[doi:10.13890/j.issn.1000-128x.2015.04.016]
YAN Zhiyong,ZENG Minggao,LUO Guoyong,et al.Parallel Control of Auxiliary Inverters for Metro Vehicle[J].Electric Drive for Locomotives,2015,(06):59.[doi:10.13890/j.issn.1000-128x.2015.04.016]
[12]赵清良,刘清,曾明高.城轨地铁车辆辅助电源系统研究与发展[J].机车电传动,2012,(01):52.[doi:10.13890/j.issn.1000-128x.2012.01.015]
[13]张勇,董兆兵,唐龙.南京地铁车辆IPM 模块国产化设计与验证[J].机车电传动,2017,(05):101.[doi:10.13890/j.issn.1000-128x.2017.05.024]
ZHANG Yong,DONG Zhaobing,TANG Long.Localization Design and Test of IPM Module in Nanjing Metro Vehicle[J].Electric Drive for Locomotives,2017,(06):101.[doi:10.13890/j.issn.1000-128x.2017.05.024]